fantozzi scale italiano fantozzi scale english fantozzi scale espanol

Dead load test Fantazzi scale LOFT LADDERS - standard UNI EN 14975:2006

Preload Kg. 100 Mean Load Kg. 160 Mean Applied Load Kg. 260 (standard UNI EN 14975:2006)
Application t (2) t=60 seconds t=60 seconds t=60 seconds
Dimensional Check Conforme
(Compliant 2 UNI EN 14975:2006)
Conforme
(Compliant 2 UNI EN 14975:2006)
Conforme
(Compliant 2 UNI EN 14975:2006)
Welding State (1) No detectable alteration No detectable alteration No detectable alteration
Spring State No detectable alteration No detectable alteration No detectable alteration
Bracket State No detectable alteration No detectable alteration No detectable alteration
The Rods No failure No failure No failure
Rung State No detectable alteration No detectable alteration Slight rung distortion.No faliure or yield reported
Folder Ladder Pack State No detectable alteration No detectable alteration No detectable alteration
ACI SVEZIA Mod.
ACI ALLUMINIO
MOTORISED LADDER Mod.
ACI TRE Mod.
ACI QUATTRO Mod.
Withstands Withstands Withstands

(2) = Application time of the kg. 100 preload, t=60 seconds as per UNI EN 14975:2006

(2) = Application time of the kg. 160, t=60 seconds as per UNI EN 14975:2006

(2) = Application time of the kg. 260, t=60 seconds as per UNI EN 14975:2006

(2) = For load tests approved weights were used, weighing kg. 20 each.

(2) = Max load tested on the middle rung: kg. 260

(1) = Welders' qualifications: ref. EN 287-1 ed EN 287-2 (manual procedures)

(1) = Welding operators' qualifications: rif. EN 1418 (automated procedures)

(1) = Welders' and welding operators in compliance with EN standards EN.

(1) = Rif. to standards on welding procedures: EN 15614-1 (steel) ed EN 15614-2 (aluminium)